SPECTRA SERIES 31
page 24). Only reports if Disarming Reporting Options (see page 36) are set to always r epor t disarming.
• REM O TE D ISARM : S y s t em i s d i s a r m e d u s i n g t h e W i nl o a d s o f t w a r e .
• KEYSWITCH DIS A RMI NG : System disarmed using a keyswitch (see page 19).
• Future use
8.2.5 ZONE ALAR M REPORT CODES
Sections [187] to [190]
A report code can be programmed for each of the 16 available zones. Whenever a zone generates an
alarm, the control panel can send the appropriate report code to the central station, identifying which zone
generated an alarm.
8.2.6 ZONE ALAR M RESTORE REPORT COD ES
Sections [191] to [194]
A report code can be programmed for each of the 16 available zones. The control panel can transmit these
report codes to the central station identifying which zone was restored.
A zone is restored when it closes after generating an alarm or once the bell has cut-off after al arm
generation. Please refer to Zone Restore Report Options on page 36.
8.2.7 SPECIAL ALAR M REPORT CODES
Sections [195] and [196]
Whenever the system generates an alarm due to one of the conditions listed below, the control panel can
send the appropriate report code to the central station identifying the type of alarm.
Section [195]
• EMERGEN CY PAN IC: Panic keys [1] and [3] have been pressed (see page 27).
• AUX IL IAR Y PANIC: Panic keys [4] and [6] have been pressed (see page 27).
• FIRE PANIC: Panic keys [7] & [9] have been pressed (see page 27).
• REC E NT CLOSING: Reports when an alarm is generated after arming the system within period defined
by the R ecent Close Delay ( see page 36).
Section [196]
• AUTO ZONE SHUTDOWN: A zone communicates more than the programmed number of transmissions
in a single armed period (see page 21).
• DURESS: A Duress access code is keyed in (see page 15).
• KEYPAD LOCKOUT: If a consecutive number of invalid codes are entered into a keypad, the control
panel can be set to deny access from all keypads for a specified period.
• Future use
8.2.8 ZONE TAMPER REPORT CODES
Section [197] to [200]
A report code can be programmed for each of the 16 available zones. Whenever a tamper or wire fault
occurs on a zone, the control panel can send the appropriate report code to the central station identifyi ng
which zone was tampered.
8.2.9 ZONE TAMPER RESTORE REP O RT CODES
Sections [201] to [204]
A report code can be programmed for each of the 16 available zones. Whenever a tampered zone is
restored, the control panel can send the appropriate report code to the central station identifying which
zone has been restored.
If Tamper Recognition (see page 27) is disabled, the control panel will not report the occurrence of
any tampers, wire faults or tamper restores.
8.2.10 SYSTEM TROUB LE REPORT CODES
Section [205] to [207]
Whenever the system generates one of the instances listed below, the control panel can send the
appropriate report code to the central station identifying the type of system trouble.
Section [205]
• Future use
• AC FAILURE: The control panel has detected a loss of AC pow er. Transmission of this report code can