DIGIPLEXNE CONTROL PANEL 11
3 PROGRAMMING METHODS
DigiplexNE can be programmed using the following methods:
3.1 WINLOAD UPLOADING/DOWNLOADING SOFTWARE*
We highly recommend programming the control panel with WinLoad as it
greatly simplifies the process and reduces potential data errors. Refer to
Winload Software on page 41 for details.
* UL Note: Not verified by UL
3.2 PARADOX MEMORY KEY (NOT TO BE USED WITH UL LISTED SYSTEMS)
The Paradox Memory Key can copy the programmed contents of one
control panel into as many others as needed. Downloading is completed in
less than 5 seconds.
Copy to Memory Key
1) Place the Memory Key on the control panel’s
connector labeled
MEM KEY. Make sure that the write
protect jumper is on.
2) Enter section:
[4020] to copy the control panel’s contents except
sections [0001] to [0096] and [0501] to [0532] to the
key.
[4021] to copy the control panel’s contents
including sections [0001] to [0096] and [0501] to [0532] to the key.
3) When the keypad emits a Confirmation Beep, remove the Memory
Key. Remove the jumper to prevent accidentally overwriting the
Memory Key’s contents.
Download to Control Panel
1) Place the Memory Key on the control panel’s
connector labeled
MEM KEY.
2) Enter section:
[4010] to download the Memory Key’s contents
except sections [0001] to [0096] and [0501] to
[0532] to the control panel.
[4011] to download the contents of the Memory Key
including sections [0001] to [0096] and [0501] to
[0532] to the control panel.
3) When the keypad emits a Confirmation Beep, remove the Memory Key.
Figure 3-1: Using the Memory Key
3.3 MODULE BROADCAST
Keypads and other modules can also be programmed easily by using
Module Broadcast (see section 11.15 on page 33). Once a module is
programmed, its sections can be sent to other similar modules through the
combus.
3.4 PROGRAMMING THROUGH A KEYPAD
Use the Programming Guide to record how the sections were programmed.
To enter programming mode:
For LCD Keypads: The control panel will save the data and automatically
advance to the next section or press the [
ENTER] key to save the data and
advance to the next section. Press the [
CLEAR] key to revert to the
preceding step or to erase the current data entry.
For Grafica Keypads: After entering the required data, press Grafica’s
center action key (Save) to save the data and advance to the next section.
Press the right action key (Exit) to revert to the preceding step or press the
left action key (Clear) to erase the current data.
3.4.1 Feature Select Programming
Most of the options are programmed using the Feature Select Method.
For LCD Keypads:
Each number from 1 to 8 corresponds to a specific
feature or option. Set these options by turning the number corresponding to
the feature ON or OFF. The option is considered ON when the number
appears within the brackets on the LCD keypad. Turn options ON and OFF by
pressing the corresponding keys on the keypad. Press the keys as many
times as needed to select the desired options and then press
[
ENTER
]
to save.
For Grafica Keypads: Select or clear the check boxes pertaining to the
options or features that you wish to enable or disable. You can also set the
options by pressing the corresponding keys on the keypad. The feature is
considered ON when its check box is selected. To save the settings, press
the Grafica’s center action key (Save).
3.4.2 Decimal Programming
Certain sections may require the entry of a 3-digit decimal value from 000
to 255.
3.4.3 Hexadecimal Programming
Certain sections may require the entry of one or more Hexadecimal values
from 0 to F. Press:
For LCD Keypads:
[0] to [9] = values 0 to 9 respectively
[
STAY] key = A [DISARM] key = D
[
FORCE] key = B [BYP] key = E
[
ARM] key = C [MEM] key = F
For Grafica Keypads:
[0] to [9] = values 0 to 9 respectively
[#] = A to F (press the key until the desired letter appears)
3.5 MODULE PROGRAMMING MODE
All modules are programmed through any LCD or Grafica keypad in the
system. To do so, enter Module Programming Mode:
The control panel will redirect all programming to the selected module. To
exit the Module Programming Mode, press the [
CLEAR] key on LCD
keypads, or the right action key (Exit) on Grafica keypads, as many times
as needed to return to the desired screen. The module's serial number can
be located on the module's PC board.
Jumper ON =
Can copy and download
contents of the Memory Key
Jumper OFF =
Cannot override contents
of the Memory Key
1) Press and hold the [0] key
2) Key in the [
INSTALLER CODE] (Default is 000000)
3) Key in the 4-digit [
SECTION]
4) Key in required [
DATA]. Refer to the Programming Guide or to the
corresponding sections in this manual.
1) Press and hold the [0] key
2) Key in the [
INSTALLER CODE] (Default is 000000)
3) Key in section [4003]
4) Key in 8-digit [
SERIAL NUMBER] of the module
5) Key in 3-digit [
SECTION] and required [DATA]. Refer to the Module
Programming Guide for details.