SEKURE DGP2-648 Installationshandbuch Seite 51

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 64
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 50
DIGIPLEXNE CONTROL PANEL 49
054 Door Forced Open Restore
000
255 = any Door
Number
Door Numbers 001 to 032 001 to 032
055 Intellizone Triggered
000 Zone Numbers 001 to 096 001 to 096
255 Any zone number Not Used Not Used
056 to 061 Future Use Future Use Future Use Future Use Future Use
062 Access Granted to User
000 User Codes 001 to 255 001 to 255 001 to 255
001 User Codes 256 to 511 000 to 255 000 to 255
002 User Codes 512 to 767 000 to 255 000 to 255
003 User Codes 768 to 999 000 to 231 000 to 231
255 Any User Code Not Used Not Used
063 Access Denied to User
000 User Codes 001 to 255 001 to 255 001 to 255
001 User Codes 256 to 511 000 to 255 000 to 255
002 User Codes 512 to 767 000 to 255 000 to 255
003 User Codes 768 to 999 000 to 231 000 to 231
255 Any User Code Not Used Not Used
064 Status 1
See NOTE 1
on page 50
Armed 000 000
Force Armed 001 001
Stay Armed 002 002
Instant Armed 003 003
Strobe Alarm 004 004
Silent Alarm 005 005
Audible Alarm 006 006
Fire Alarm 007 007
065 Status 2
See NOTE 1
on page 50
Ready 000 000
Exit Delay 001 001
Entry Delay 002 002
System in Trouble 003 003
Alarm in Memory 004 004
Zones Bypassed 005 005
Bypass, Master, Installer Programming 006 006
Keypad Lockout 007 007
066 Status 3
See NOTE 1
on page 50
Intellizone Delay Engaged
(see NOTE 4 on page 50)
000 000
Fire Delay Engaged 001 001
Auto Arm 002 002
Arming with Voice Module (set until
Exit Delay finishes)
003 003
Tamper 004 004
Zone Low Battery 005 005
Fire Loop Trouble 006 006
Zone Supervision Trouble 007 007
067 Special Status N/A
Chime in Partition 1 to 4
(000 to 003 = System 1 to 4)
000 to 003 000 to 003
Smoke Detector Power Reset 004 004
Ground Start 005 005
Kiss Off 006 006
Telephone Ring 007 007
Bell on Partition 1 to 8
(008 to 015 = Partitions 1 to 8)
008 to 015 008 to 015
Fire Alarm in Partition 1 to 8
(016 to 023 = Partitions 1 to 8)
016 to 023 016 to 023
Open/close Kiss Off in Partition 1 to 8
(024 to 031 = Partitions 1 to 8)
024 to 031 024 to 031
Keyswitch/PGM Inputs # 01 to 32
(032 to 063 = Keyswitch/PGM Inputs #
01 to 32)
032 to 063 032 to 063
Status of Access Door 01 to 32
(064 to 095 = Access Doors 01 to 32)
064 to 095 064 to 095
Trouble in System 096 096
Event Group Event Feature Group Feature Start # End #
Seitenansicht 50
1 2 ... 46 47 48 49 50 51 52 53 54 55 56 ... 63 64