OBD 187
OSCILLOSCOPE
Press 5 to select <OSCILLOSCOPE> from the <AUTOPROBE MENU>. The
Oscilloscope mode displays voltage signals from the Autoprobe for real-time analysis.
The status line at the top of the display indicates the current settings for the Oscilloscope
display.
DISPLAY CONTROL
The Oscilloscope Mode display configuration may be adjusted to display the data in
different formats. The Display Control menu at the bottom indicates keys that are used to
change the Oscilloscope settings. The u and d keys are used to change the
highlighted setting. To adjust a different setting, press the key which corresponds with the
number to the left of the setting to be changed.
1. TIME Use u and d to change the Time Scale. The supported time per
division scaling is: .2ms, .5ms, 1ms, 2ms, 5ms, 10ms, 20ms, 50ms, 0.1s,
1s, 2s, 5s, 10s, 20s, 50s.
2. VOLT Use u and d to change the Volt Scale. The supported volts per
division scaling is: 0.1V, 0.2V, 0.5V, 1V, 2V, 5V.
3. LVL Use u and d to make coarse adjustments to the trigger level.
Trigger level is set in 1/2 division increments. Use au and ad
to make fine adjustments to the trigger level.
4. GND Use u and d to change the GND level. The trigger level indicator
moves along with the GND level.