Figure 3-4: Sample Power Requirement Calculations
An LCD Keypad (80PU) can be added to the 100ft. or 300ft. wire in Figure
3-4, but adding an LCD Keypad to the 1000ft. wire would exceed the wires
limits and cause devices to function at decreased capacity.
Figure 3-5: External Power Supply Connections
Do not use the same transformer for the control panel and the
external power supplies. Do not install modules more than
3000ft (914m) from the control panel.
3.12 K
EYPAD
Z
ONE
C
ONNECTIONS
Each keypad has one hardwired input terminal allowing you to connect a
detector or door contact directly to the keypad. For example, a door contact
located at the entry point of an establishment can be wired directly to the
input terminal of the entry point keypad instead of back to the control panel.
Even with the ATZ feature enabled in the control panel, only
one device can be connected to the keypad’s hardwired input
terminal. Tamper is not recognized on keypad zones. The
keypad zone follows the control panel’s EOL definition.
A device connected to the keypad’s input terminal must be assigned to a
zone in the control panel and the zone’s parameters must be defined (see
Zone Programming on page 16). The keypad uses GuardWall technology
to communicate the status of the zone to the control panel via the
communication network. The detection device is connected as shown in
Figure 3-3 on page 10.
3.13 A
DDRESSABLE
Z
ONE
C
ONNECTIONS
The control panel includes eight hardwired input terminals for use with
traditional hardwired (non-network) door contacts, smoke detectors and/or
motion detectors.
The control panel also supports several hardwire zone expansion modules.
Devices connected to hardwired input terminals must be assigned to a
zone and the zone's parameters must be defined (see Zone Programming
on page 16). Figure 3-6 shows single zone (ATZ disabled) hardwire input
terminal connections recognized by the DigiplexNE system. For UL listed
installations, use EOL resistor part #2011002000.
As indicated in Table 2 on
page 11, this run of wire can
support 700PU. Total PU on
this run of wire:
(A) 40PU + (B) 40PU =
80PU<700PU = OK
As indicated in Table 2
on page 11, this run of
wire can support 454PU.
Total PU on this run of
wire:
(D) 60PU + (E) 16PU +
(F) 60PU + (G) 60PU
= 196PU<454PU = OK
As indicated in Table 2 on
page 11, this run of wire
can support 136PU. Total
PU on this run of wire:
(A) 40PU + (C) 16PU =
56PU<136PU = OK