36 R
EFERENCE
& I
NSTALLATION
M
ANUAL
12.8 S
YSTEM
D
ATE
& T
IME
The System Date and Time is programmed through the User Menu, please
refer to Clock Loss in section 16.11.
12.9 S
HABBAT
F
EATURE
(Default = disabled) When option [4] is enabled, detectors and keypads in
the system no longer display system status through the LCD and/or LEDs
between noon (12:00PM) Friday and midnight (12:00AM) Saturday. Normal
operation is re-instated Sunday morning at 12:00:01AM. If required, a user
can access all the usual commands and features during the Shabbat period
by pressing a key or by entering their access code (also depending if and
how Confidential Mode is enabled in the keypad). When no actions have
occurred for two minutes, the Shabbat Feature will re-activate. During the
Shabbat period:
the LCD keypads only display the date and time
the backlight is disabled
the LED indicators on modules with GuardWall technology are disabled
12.10 I
NSTALLER
F
UNCTION
K
EYS
Press and hold the [0] key and key in the [
INSTALLER
CODE
] to access the
following function keys.
12.11 M
ODULE
R
ESET
To reset a module connected to the communication network to its default
values, key in the module's serial number into section [4001].
12.12 L
OCATE
M
ODULE
To locate a specific module on the communication network, key in the
module's serial number into section [4002]. The green
LOCATE
LED on the
module flashes until the serial number is re-entered into the section or the
modules tamper or unlocate switch is pressed.
12.13 M
ODULE
P
ROGRAMMING
All modules with GuardWall technology connected to the communication
network are programmed through the control panel. To program a module,
enter section [4003] to enter Module Programming Mode (see section 4.5),
key in the module's serial number and follow the programming indicated in
the DigiplexNE Modules Programming Guide. To exit this mode, press the
[
CLEAR
] key until Normal Mode is displayed.
12.14 M
ODULE
B
ROADCAST
To copy the contents of the programming sections from one module with
GuardWall technology to one or more of the same type, key in the serial
number of the source module in section [4004], then enter the serial
numbers of all the destination modules and press [
ACC
].
For example, to program two zone expansion modules (SN#34540075 and
SN#34412100) with the same settings and options of zone expansion
module SN#34540033:
1) Press and hold the [0] key
2) Key in the Installer Code
3) Enter [4004]
4) Enter 34540033, 34540075, and 34412100
5) Press [ACC]
The control panel automatically copies the contents of 34540033 into the
other two zone expansion modules.
12.15 L
ABEL
B
ROADCAST
Enter section [4006] to copy the User Labels, Zone Labels (sections [0301]
to [0396]), the Door Labels (sections [2301] to [2332]) and the Partition
Labels (sections [3100], [3200], [3300], [3400], [3500], [3600], [3700] and
[3800]) to all the modules in the system that support these labels.
12.16 R
EMOVE
M
ODULE
After entering section [4005], the control panel scans all modules on the
communication network. If modules are missing (i.e. module was removed)
during this scan, the control panel erases the module's serial number and
removes the module from the control panel's memory.
12.17 S
ERIAL
N
UMBER
V
IEWING
Enter section [4000] to view the serial number of the control panel as well
as the serial numbers of all modules with GuardWall technology on the
communication network. The keypad displays the eight-digit serial number
of the control panel. Use the [
] and [ ] keys to scroll through the serial
number of each module.
12.18 P
OWER
S
AVE
M
ODE
(Default = enabled) When option [4] is enabled and the control panel is
running on the backup battery (no AC), the control panel can set all
keypads into a sleep mode or Power Save Mode. In Power Save Mode
the keypad's backlight and LEDs are disabled until a key is pressed, an
alarm occurs or an Entry Delay is triggered.
12.19 A
UTO
T
ROUBLE
S
HUTDOWN
(Default = 00) If, in a 24-hour period, a trouble occurs more than the
number of times programmed in section [3021], the control panel stops
reporting the trouble. Enter a value (01 to 15, 00 = disabled) into section
[3021]. Each trouble has its own counter. The counter is reset every day at
midnight.
Keys Description
[
STAY
]
TEST REPORT
Sends the Test Report report code programmed in section
[3902] to the Monitoring Station.
[
FORCE
]
CALL WINLOAD:
Dials the PC telephone number programmed in section [3010] to
communicate with a computer using WinLoad.
[
ARM]
ANSWER WINLOAD:
Forces the control panel to answer a call made by the Central
Monitoring Station that is using WinLoad.
[
DISARM
]
CANCEL COMMUNICATION
Cancels all communication with the Monitoring Station or
WinLoad until the next reportable event.
[
MEM
]
INSTALLER TEST MODE
Perform walk tests where the bell or siren squawks once when a
zone opens and twice when it closes. Press [
MEM] again to exit.
Partitions cannot be armed if the Installer Test Mode is enabled.
[
TRBL]
START MODULE SCAN
Verifies the status of modules on the communication network.
The LCD Keypads display the serial number of each module
connected to the communication network.
[
ACC
]
START VOLTMETER READING:
Verifies if the communication network is supplying sufficient
power at the keypads location (refer to the Digiplex/DigiplexNE
LCD Keypad and Access Control LCD Keypad Reference &
Installation Manual).