44 R
EFERENCE
& I
NSTALLATION
M
ANUAL
16.1 R
EGULAR
A
RMING
This method is used for the everyday arming of the system. All zones within
the partition must be closed to arm the system. The system can also be
Regular Armed by using a One-touch Feature (see section 7.14) or a
Keyswitch (see section 6.4.3). All users are able to Regular Arm the
partition(s) assigned to their User Access Codes. To Regular Arm, users:
1) Enter their [
ACCESS
CODE
]
2) Press the [
ARM
] key. If the code is assigned to several partitions, press
the key corresponding to the desired partition or press [0] to arm all
their assigned partitions.
16.2 S
TAY
A
RMING
Stay Arming partially arms the partition to permit the user to remain in the
partition. Stay Zones (see section 5.5.3) will not arm when Stay Arming.
Partitions can also be armed by the Stay Arm One-touch Feature (see
section 7.14) or a Keyswitch (see section 6.4.4). Only User Access Codes
with the Stay and Instant Arm option enabled can Stay Arm a partition.
For example, arm the doors and windows without arming the motion
detectors.
To Stay Arm, users:
1) Enter their [
ACCESS
CODE
]
2) Press the [
STAY
] key. If the users have access to more than one
partition, they can press the key corresponding to the desired partition
or press [0] to arm all their assigned partitions.
16.2.1 Stay Arming with Delay
Stay Arming with Delay functions like Stay Arming except armed zones are
programmed with an Entry Delay Timer (see section 5.3.14). If a zone is
triggered, the delay starts allowing the user time to disarm the partition(s).
16.3 I
NSTANT
A
RMING
Similar to Stay Arming, Instant Arming partially arms the partition to permit
the user to remain in the partition, but all zones become Instant zones.
Partitions can also be armed by the Instant One-touch Feature (see section
7.14) or a Keyswitch (see section 6.4.6). Only User Access Codes with the
Stay and Instant Arm option enabled can Instant Arm a partition. To Instant
Arm, users:
1) Enter their [
ACCESS
CODE
]
2) Press the [5] key. If the users have access to more than one partition,
they can press the key corresponding to the desired partition or press
[0] to arm all their assigned partitions.
16.3.1 Instant Arming with Delay
Instant Arming with Delay functions like Instant Arming except armed zones
are programmed with an Entry Delay Timer (see section 5.3.14). If a zone
is triggered, the delay starts allowing the user time to disarm the partitions.
16.4 F
ORCE
A
RMING
Force Arming allows the user to arm a partition when Force zones are open
(see section 5.5.4). Once the open zone in an armed partition is closed,
the system will then arm it as well. This feature is commonly used when a
motion detector is protecting an area that is occupied by a keypad. The
system can also be Force Armed by using a One-touch Feature (see
section 7.14) or a Keyswitch (see section 6.4.5). Only User Access Codes
with the Force Arm option enabled can Force Arm a partition.
For example, during Force arming the motion detector remains unarmed
until the user exits the area. The system will then arm the motion detector.
To Force Arm, users:
1) Enter their [
ACCESS
CODE
]
2) Press the [
FORCE
] key. If the users have access to more than one
partition, they can press the key corresponding to the desired partition
or press [0] to arm all their assigned partitions.
16.5 D
ISARMING
All users can disarm, except users with Arm Only (see section 13.5)
enabled on their User Access Codes. Users can only disarm the partitions
assigned to their User Access Codes. The Stay or Instant Armed partitions
can also be Disarmed by using a One-touch Feature. To disarm, users:
1) Enter through a designated entry. The Entry Delay Timer will begin.
2) Enter their [
ACCESS
CODE
]
3) Press the [
DISARM
] key
16.6 B
YPASS
P
ROGRAMMING
Bypass Programming allows users to program the security system to ignore
specified zones the next time the partition is armed. To bypass a zone, the
zone must have the Bypass option enabled, the User Access Code must
have the Bypass option enabled, and the zone must be within the User
Access Code’s partition assignment. To Bypass, users:
1) Enter their [
ACCESS
CODE
]
2) Press the [
BYP
] key
3) Enter the zone’s 2-digit number or use the [
] and [ ] keys and
press the [
BYP] key when the zone appears on-screen.
4) Press [
ENTER
] key to exit
Users can also activate Bypass Recall. Bypass Recall reinstates all the
zones that were bypassed the last time the partition(s) assigned to the User
Access Code were armed. To activate Bypass Recall, users:
1) Enter their [
ACCESS
CODE
]
2) Press the [
BYP
] key
3) Press the [
MEM] key
4) Press [
ENTER
] key to exit
16.7 C
HIME
Z
ONES
The keypads can emit rapid, intermittent beeps whenever designated
zones within their assigned partitions open or when they open during a time
period. To program a Chime Zone, users:
1) Enter their [
ACCESS CODE]
2) Press the [9] key
3) Press the [1] key
4) Enter the zone’s 2-digit number or use the [
] and [ ] keys to scroll
the list and press the [
ACC
] key when the zone appears on-screen
5) Press [
ENTER] key to save
To program a time period when the Chime Zones are activated, users:
1) Enter their [
ACCESS CODE]
2) Press the [9] key
3) Press the [2] key
4) Enter the time that keypads will start beeping when Chime Zones are
opened according to the 24-hour clock (i.e. 9PM is 21:00).
5) Enter the time that keypads will stop beeping when Chime Zones are
opened according to the 24-hour clock (i.e. 9PM is 21:00).
6) Press [
ENTER
] key to save
16.8 K
EYPAD
S
ETTINGS
The keypad’s settings can be modified to suit the user’s needs. Scrolling
Speed is how long the messages stay on the LCD screen before moving to
the next message. Backlight: is the illumination behind the keys and the
screen. Contrast: is how dark the characters appear on the LCD screen.
1) Enter the [
USER
ACCESS
CODE
]
2) Press [6]
3) Press [1]: Scrolling Speed from 0 to 10 (10 = slowest)
Press [2]: Backlight from 0 to 7 (7 = brightest)
Press [3]: Contrast from 0 to 4 (4 = most contrast)
4) Use the [
] and [ ] keys to increase or decrease the numbers
5) Press [
ENTER
]
6) Press [
CLEAR
] to exit or the [ ] key to move to the next setting